{"id":173,"date":"2018-04-10T21:50:35","date_gmt":"2018-04-10T21:50:35","guid":{"rendered":"https:\/\/blog.xn--calderasdegasycalefaccioncorua-64c.es\/blog\/?p=173"},"modified":"2023-12-10T14:49:52","modified_gmt":"2023-12-10T14:49:52","slug":"calefaccion-y-radiadores-de-baja-temperatura","status":"publish","type":"post","link":"https:\/\/blog.xn--calderasdegasycalefaccioncorua-64c.es\/blog\/eficiencia-energetica\/calefaccion-y-radiadores-de-baja-temperatura\/","title":{"rendered":"Calefacci\u00f3n y radiadores de baja temperatura"},"content":{"rendered":"<p style=\"text-align: justify;\"><span style=\"font-size: 12pt; color: #000000;\">Las nuevas necesidade de ahorro y eficiencia nos encaminan a convertir nuestra instalaci\u00f3n t\u00e9rmica en invierno en una <strong>calefacci\u00f3n y radiadores de baja temperatura<\/strong>.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-size: 12pt; color: #000000;\">Los radiadores convencionales comunes que todos conocemos, ya sean aluminio, chapa o de fundici\u00f3n, necesitamos hacerlos trabajar con altas temperaturas de agua, para aportar la potencia calor\u00edfica para la que han sido dise\u00f1ados. Esto produce que, si a la hora de renovar nuestra caldera por una de condensaci\u00f3n que est\u00e1n optimizadas para trabajar a bajas temperaturas de emisi\u00f3n, o que estemos pensando en instalar en nuestro hogar una <a title=\"Que es la aerotermia\" href=\"https:\/\/blog.xn--calderasdegasycalefaccioncorua-64c.es\/blog\/eficiencia-energetica\/que-es-la-aerotermia\/\">aerotermia<\/a> o una <a title=\"Que es la geotermia\" href=\"https:\/\/blog.xn--calderasdegasycalefaccioncorua-64c.es\/blog\/climatizacion\/que-es-la-geotermia\/\">geotermia<\/a>; este tipo de emisores no sean los m\u00e1s eficientes, por lo que el ahorro energ\u00e9tico y el confort t\u00e9rmico que podr\u00edamos obtener no ser\u00e1 el \u00f3ptimo.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-size: 12pt; color: #000000;\">Desde siempre los radiadores convencionales trabajan con saltos t\u00e9rmicos elevados, es decir, que necesitan una entrada y una salida de agua a elevada temperatura:<\/span><\/p>\n<p><img data-recalc-dims=\"1\" fetchpriority=\"high\" decoding=\"async\" class=\"alignnone wp-image-184 \" src=\"https:\/\/i0.wp.com\/blog.xn--calderasdegasycalefaccioncorua-64c.es\/blog\/wp-content\/uploads\/2018\/04\/saltotermicoenradiador.png?resize=586%2C323&#038;ssl=1\" alt=\"\" width=\"586\" height=\"323\" srcset=\"https:\/\/i0.wp.com\/blog.xn--calderasdegasycalefaccioncorua-64c.es\/blog\/wp-content\/uploads\/2018\/04\/saltotermicoenradiador.png?w=657&amp;ssl=1 657w, https:\/\/i0.wp.com\/blog.xn--calderasdegasycalefaccioncorua-64c.es\/blog\/wp-content\/uploads\/2018\/04\/saltotermicoenradiador.png?resize=300%2C165&amp;ssl=1 300w\" sizes=\"(max-width: 586px) 100vw, 586px\" \/><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-size: 12pt; color: #000000;\">Tradicionalmente, en un radiador convencional, el agua procedente de la caldera entra a 75\u00baC y sale a 65\u00baC en condiciones normales.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-size: 12pt; color: #000000;\">En la actualidad, la eficiencia energ\u00e9tica\u00a0 intenta reducir al m\u00e1ximo la diferencia de temperatura entre la temperatura del agua de calefacci\u00f3n\u00a0 y la del ambiente. El Reglamento de Instalaciones T\u00e9rmicas en Edificios, desde el 2013 fija que el salto t\u00e9rmico para el calculo de emisores de calefacci\u00f3n sea de 40\u00ba, lo que nos obliga a tener una temperatura media del radiador de 60\u00ba.<\/span><!--more--><\/p>\n<h5><span style=\"color: #000000;\">Tipos de radiadores a baja temperatura<\/span><\/h5>\n<p style=\"text-align: justify;\"><span style=\"font-size: 12pt; color: #000000;\">Actualmente tenemos dos formas de trabajar con radiadores de baja temperatura:<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-size: 12pt; color: #000000;\">La primera que se ha venido desarrollando ya fuertemente en los \u00faltimos a\u00f1os es la conocida como \u00abradiadores LOW H2O\u00bb\u00a0 o de baja carga de agua como los de la marca\u00a0 JAGA.\u00a0 \u00a0estos radiadores\u00a0<strong>contienen entre un 80%-90% menos de agua<\/strong>\u00a0que un radiador convencional, reduciendo la cantidad de masa que tienen que calentar para producir calor.\u00a0El intercambiador de calor, por lo general, suele ser de un aleteado de aluminio implementando tuber\u00edas de cobre que transfieren el calor a la habitaci\u00f3n inmediatamente.\u00a0 Es la opci\u00f3n m\u00e1s cara pero m\u00e1s eficiente, y la desarrollaremos en un articulo posterior.<\/span><\/p>\n<figure id=\"attachment_176\" aria-describedby=\"caption-attachment-176\" style=\"width: 300px\" class=\"wp-caption alignnone\"><img data-recalc-dims=\"1\" decoding=\"async\" class=\"size-medium wp-image-176\" src=\"https:\/\/i0.wp.com\/blog.xn--calderasdegasycalefaccioncorua-64c.es\/blog\/wp-content\/uploads\/2018\/01\/radiador-baja-temperatura.jpg?resize=300%2C242&#038;ssl=1\" alt=\"Radiador baja temperatura\" width=\"300\" height=\"242\" srcset=\"https:\/\/i0.wp.com\/blog.xn--calderasdegasycalefaccioncorua-64c.es\/blog\/wp-content\/uploads\/2018\/01\/radiador-baja-temperatura.jpg?resize=300%2C242&amp;ssl=1 300w, https:\/\/i0.wp.com\/blog.xn--calderasdegasycalefaccioncorua-64c.es\/blog\/wp-content\/uploads\/2018\/01\/radiador-baja-temperatura.jpg?w=550&amp;ssl=1 550w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><figcaption id=\"caption-attachment-176\" class=\"wp-caption-text\">Radiadores baja temperatura LOW H2O<\/figcaption><\/figure>\n<p style=\"text-align: justify;\"><span style=\"font-size: 12pt; color: #000000;\">La otra opci\u00f3n consiste en sobredimensionar\u00a0\u00a0la instalaci\u00f3n. Esta opci\u00f3n es la m\u00e1s econ\u00f3mica y viable en muchos casos, especialmente en vivienda antigua, ya que la instalaci\u00f3n de los radiadores LOW H2O requieren tambi\u00e9n de una conexi\u00f3n el\u00e9ctrica. Sobredimensionando los radiadores, conseguiremos calefactar con las mismas calor\u00edas a menor temperatura, a costa de aumentar el tama\u00f1o de los emisores.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #000000;\"><span style=\"font-size: 12pt;\">Tradicionalmente, en un radiador convencional, trabajando con calderas de no condensaci\u00f3n el agua procedente del sistema de generaci\u00f3n de calor entra sobre 75\u00baC y sale a 65\u00baC.\u00a0<\/span><span style=\"font-size: 12pt;\">Actualmente el Reglamento de Instalaciones T\u00e9rmicas en Edificios, desde el 2013 se fija una temperatura media del radiador de 60\u00baC con \u00a0lo que el salto t\u00e9rmico con el que hay que calcular la necesidad de emisores de calefacci\u00f3n es de 40\u00ba.\u00a0 Con esta temperatura media estar\u00edamos consiguiendo rendimientos superiores al 95% en una caldera e condensaci\u00f3n. Si el calculo lo realizamos para una temperatura media de 50\u00baC estar\u00edamos hablando ya de rendimientos del 100%.<\/span><\/span><\/p>\n<h2 style=\"text-align: justify;\"><span style=\"color: #000000;\">\u00bfEs Necesario cambiar la instalaci\u00f3n existente para disponer de calefacci\u00f3n con radiadores de baja temperatura?<\/span><\/h2>\n<p style=\"text-align: justify;\"><span style=\"font-size: 12pt; color: #000000;\">Cada caso debe\u00a0ser analizado individualmente. Si tenemos una instalaci\u00f3n de radiadores convencionales calculados para trabajar a alta temperatura, y ahora instalamos una caldera de condensaci\u00f3n o una bomba de calor, es altamente posible que si necesitemos aumentar el n\u00famero de elementos, o elegir unos elementos m\u00e1s eficientes. Debemos de\u00a0 tener en cuenta tambi\u00e9n\u00a0 que en muchas de nuestras viviendas muy probablemente hayamos realizado a lo largo de los a\u00f1os obras en fachadas que mejoren el aislamiento, o cambio de ventanas que minimicen las perdidas calor\u00edficas; cosas todas ellas que provocan un menor numero de calor\u00edas para calefactar la estancia.<\/span><\/p>\n<p><img data-recalc-dims=\"1\" decoding=\"async\" class=\"alignleft size-medium wp-image-332\" src=\"https:\/\/i0.wp.com\/blog.xn--calderasdegasycalefaccioncorua-64c.es\/blog\/wp-content\/uploads\/2022\/08\/GridArt_20220829_225250761.jpg?resize=300%2C300&#038;ssl=1\" alt=\"calefacci\u00f3n y radiadores de baja temperatura\" width=\"300\" height=\"300\" srcset=\"https:\/\/i0.wp.com\/blog.xn--calderasdegasycalefaccioncorua-64c.es\/blog\/wp-content\/uploads\/2022\/08\/GridArt_20220829_225250761-scaled.jpg?resize=300%2C300&amp;ssl=1 300w, https:\/\/i0.wp.com\/blog.xn--calderasdegasycalefaccioncorua-64c.es\/blog\/wp-content\/uploads\/2022\/08\/GridArt_20220829_225250761-scaled.jpg?resize=1024%2C1024&amp;ssl=1 1024w, https:\/\/i0.wp.com\/blog.xn--calderasdegasycalefaccioncorua-64c.es\/blog\/wp-content\/uploads\/2022\/08\/GridArt_20220829_225250761-scaled.jpg?resize=150%2C150&amp;ssl=1 150w, https:\/\/i0.wp.com\/blog.xn--calderasdegasycalefaccioncorua-64c.es\/blog\/wp-content\/uploads\/2022\/08\/GridArt_20220829_225250761-scaled.jpg?resize=768%2C768&amp;ssl=1 768w, https:\/\/i0.wp.com\/blog.xn--calderasdegasycalefaccioncorua-64c.es\/blog\/wp-content\/uploads\/2022\/08\/GridArt_20220829_225250761-scaled.jpg?resize=1536%2C1536&amp;ssl=1 1536w, https:\/\/i0.wp.com\/blog.xn--calderasdegasycalefaccioncorua-64c.es\/blog\/wp-content\/uploads\/2022\/08\/GridArt_20220829_225250761-scaled.jpg?resize=2048%2C2048&amp;ssl=1 2048w, https:\/\/i0.wp.com\/blog.xn--calderasdegasycalefaccioncorua-64c.es\/blog\/wp-content\/uploads\/2022\/08\/GridArt_20220829_225250761-scaled.jpg?w=1280&amp;ssl=1 1280w, https:\/\/i0.wp.com\/blog.xn--calderasdegasycalefaccioncorua-64c.es\/blog\/wp-content\/uploads\/2022\/08\/GridArt_20220829_225250761-scaled.jpg?w=1920&amp;ssl=1 1920w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-size: 12pt; color: #000000;\">Es por ello que el profesional debe \u00a0realizar un nuevo calculo de las necesidades calor\u00edficas de la vivienda y\u00a0 efectuar un nuevo dimensionamiento de la instalaci\u00f3n bas\u00e1ndose en la formula siguiente:\u00a0<b>\u00a0 \u00a0 <\/b><\/span><span style=\"font-size: 12pt; color: #000000;\"><b>\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0\u00a0<\/b><\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-size: 12pt; color: #000000;\"><b>\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0<em>\u00a0<\/em><\/b><em><strong>\u2206T = (T\u00aa ida calefacci\u00f3n + T\u00aa retorno calefacci\u00f3n) \/ 2 \u2013 T\u00aa ambiente.<\/strong><\/em>\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-size: 12pt; color: #000000;\"> En nuestro caso con una temperatura media de 60\u00baC y 20\u00baC de temperatura en el local a calefactar obtenemos una \u2206T= 40\u00baC, con la que acudimos\u00a0 a los datos de referencia que da el fabricante de los radiadores .\u00a0\u00a0<\/span><\/p>\n<p style=\"text-align: justify;\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-179 size-full\" src=\"https:\/\/i0.wp.com\/blog.xn--calderasdegasycalefaccioncorua-64c.es\/blog\/wp-content\/uploads\/2018\/04\/emisiones-dubal.jpg?resize=640%2C167&#038;ssl=1\" alt=\"\" width=\"640\" height=\"167\" srcset=\"https:\/\/i0.wp.com\/blog.xn--calderasdegasycalefaccioncorua-64c.es\/blog\/wp-content\/uploads\/2018\/04\/emisiones-dubal.jpg?w=902&amp;ssl=1 902w, https:\/\/i0.wp.com\/blog.xn--calderasdegasycalefaccioncorua-64c.es\/blog\/wp-content\/uploads\/2018\/04\/emisiones-dubal.jpg?resize=300%2C78&amp;ssl=1 300w, https:\/\/i0.wp.com\/blog.xn--calderasdegasycalefaccioncorua-64c.es\/blog\/wp-content\/uploads\/2018\/04\/emisiones-dubal.jpg?resize=768%2C200&amp;ssl=1 768w\" sizes=\"(max-width: 640px) 100vw, 640px\" \/><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-size: 12pt; color: #000000;\">En este caso vamos a elegir unos radiadores Baxi Dubal en donde nos podemos dar cuenta de la diferencia que existe entre el n\u00famero de elementos que hacen falta entre trabajar a una temperatura media de 70\u00baC o 60\u00baC. (columnas n\u00ba 2 y 3) M\u00e1s de un 35% de diferencia.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-size: 12pt; color: #000000;\">confrontando los datos de necesidades calor\u00edficas obtenidos anteriormente, con los datos de superficie de radiador que necesitamos con baja temperatura, ya sabemos si es suficiente la instalaci\u00f3n existente o la necesitamos aumentar.\u00a0<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-size: 12pt; color: #000000;\">En una obra nuevas el CTE (C\u00f3digo T\u00e9cnico de la Edificaci\u00f3n)\u00a0 nos obliga ya hoy en d\u00eda a unos aislamientos t\u00e9rmicos que disminuyen en mucho las perdidas calor\u00edficas de la vivienda; (M\u00e1s de un 35% respecto al anterior NBE-CT79). Menor perdida calor\u00edfica significa menor demanda t\u00e9rmica y menor n\u00famero de radiadores.\u00a0 Con lo cual hoy en viviendas nuevas con radiadores del mismo tama\u00f1o que los usados con anterioridad en viviendas con peor aislamiento podremos trabajar a temperaturas medias de radiador m\u00e1s bajas.<\/span><\/p>\n<h5><span style=\"color: #000000;\">Ventajas de los radiadores a baja temperatura<\/span><\/h5>\n<ul>\n<li style=\"text-align: justify;\"><span style=\"font-size: 12pt; color: #000000;\">Facilidad de instalaci\u00f3n tanto en obra nueva como de adecuaci\u00f3n de la ya existente.<\/span><\/li>\n<li style=\"text-align: justify;\"><span style=\"font-size: 12pt; color: #000000;\">Es la opci\u00f3n m\u00e1s econ\u00f3mica en comparaci\u00f3n a otros sistemas de calefacci\u00f3n<\/span><\/li>\n<li style=\"text-align: justify;\"><span style=\"font-size: 12pt; color: #000000;\">Mayor eficiencia energ\u00e9tica, ya que una temperatura de impulsi\u00f3n baja produce menos perdidas y aumenta la eficiencia de los generadores t\u00e9rmicos actuales (<a href=\"https:\/\/blog.xn--calderasdegasycalefaccioncorua-64c.es\/blog\/eficiencia-energetica\/que-es-la-aerotermia\/\">aerotermia<\/a>, condensaci\u00f3n, geotermia&#8230;)<\/span><\/li>\n<li style=\"text-align: justify;\"><span style=\"font-size: 12pt; color: #000000;\">Mayor calidad y confort de calor ya que en un radiador convencional con impulsi\u00f3n superior a 70\u00baC\u00a0, aproximadamente el 80% de la transmisi\u00f3n de calor es por convenci\u00f3n y el 20% por radiaci\u00f3n, en el caso de los radiadores de baja temperatura podr\u00edamos decir que la emisi\u00f3n de calor se produce por\u00a0convenci\u00f3n, por lo que aumenta as\u00ed la sensaci\u00f3n de confort y la emisi\u00f3n se produce de forma m\u00e1s eficiente.\u00a0En el caso de los radiadores a baja temperatura, al ser una temperatura m\u00e1s baja, unos 50\u00ba por ejemplo, el calor se emite por radiaci\u00f3n, el calor se emite de forma m\u00e1s directa y sin zonas con golpes de aire excesivamente c\u00e1lido y seco.<\/span><\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Las nuevas necesidade de ahorro y eficiencia nos encaminan a convertir nuestra instalaci\u00f3n t\u00e9rmica en<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"jetpack_post_was_ever_published":false,"footnotes":""},"categories":[4,18],"tags":[20,19],"class_list":["post-173","post","type-post","status-publish","format-standard","hentry","category-eficiencia-energetica","category-radiadores","tag-baja-temperatura","tag-radiadores"],"aioseo_notices":[],"jetpack_featured_media_url":"","jetpack_shortlink":"https:\/\/wp.me\/ph9KVn-2N","jetpack_likes_enabled":true,"jetpack-related-posts":[],"_links":{"self":[{"href":"https:\/\/blog.xn--calderasdegasycalefaccioncorua-64c.es\/blog\/wp-json\/wp\/v2\/posts\/173","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blog.xn--calderasdegasycalefaccioncorua-64c.es\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blog.xn--calderasdegasycalefaccioncorua-64c.es\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blog.xn--calderasdegasycalefaccioncorua-64c.es\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/blog.xn--calderasdegasycalefaccioncorua-64c.es\/blog\/wp-json\/wp\/v2\/comments?post=173"}],"version-history":[{"count":5,"href":"https:\/\/blog.xn--calderasdegasycalefaccioncorua-64c.es\/blog\/wp-json\/wp\/v2\/posts\/173\/revisions"}],"predecessor-version":[{"id":430,"href":"https:\/\/blog.xn--calderasdegasycalefaccioncorua-64c.es\/blog\/wp-json\/wp\/v2\/posts\/173\/revisions\/430"}],"wp:attachment":[{"href":"https:\/\/blog.xn--calderasdegasycalefaccioncorua-64c.es\/blog\/wp-json\/wp\/v2\/media?parent=173"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blog.xn--calderasdegasycalefaccioncorua-64c.es\/blog\/wp-json\/wp\/v2\/categories?post=173"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blog.xn--calderasdegasycalefaccioncorua-64c.es\/blog\/wp-json\/wp\/v2\/tags?post=173"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}